Uterine Perforation After Childbirth: CT Findings of an Extrauterine IUD, Sentinel Clot, and Hemoperitoneum

 


How to Recognize Complete Uterine Perforation in a Postpartum Patient With Abdominal Pain and Missing IUD Strings

Author: Dr. SangBock Lee
Publication: ScholarGen MediAI
Tagline: Where Medical Imaging & AI Meets Humanity

Executive Answer: What Does CT Show in Uterine Perforation After IUD Insertion?

Uterine perforation is an uncommon but potentially serious complication of intrauterine device (IUD) placement. In a postpartum patient presenting with abdominal pain and nonvisible IUD strings, contrast-enhanced computed tomography (CT) can identify complete uterine perforation, extrauterine device migration, and associated intra-abdominal bleeding. In this case, CT demonstrated a full-thickness defect at the uterine fundus, an adjacent sentinel clot, an IUD within the pelvic cavity, and hemoperitoneum. These findings prompted urgent surgical exploration, which confirmed the perforation and the displaced device. The central diagnostic lesson is to evaluate the integrity of the uterine wall and the presence of hemorrhage, rather than focusing exclusively on the location of the device.

Why This Case Matters

An intrauterine device is a highly effective method of long-term contraception. Nevertheless, abdominal or pelvic pain after insertion requires careful assessment when the IUD strings are no longer visible.

The combination of postpartum status, abdominal pain, and missing IUD strings raises several possibilities, including string retraction, device expulsion, malposition, embedment, partial perforation, and complete uterine perforation with migration into the peritoneal cavity.

The distinction matters because these conditions do not carry the same clinical implications. A device that remains within the uterine cavity but is abnormally positioned may require a different management strategy from one that has traversed the entire uterine wall and is associated with intra-abdominal bleeding.

This case illustrates a particularly important diagnostic combination:

  • A full-thickness uterine fundal defect.

  • An adjacent sentinel clot.

  • An IUD outside the uterine cavity, within the pelvis.

  • Hemoperitoneum.

Together, these findings strongly support complete uterine perforation with extrauterine IUD migration and associated bleeding.

The case also demonstrates why cross-sectional imaging can be decisive in acute presentations: CT evaluates the uterus, the displaced device, the distribution of blood, and the surrounding abdominal and pelvic structures in a single examination.

Clinical Presentation: Abdominal Pain 40 Days After Delivery

The patient was a 30-year-old woman who developed abdominal pain approximately 40 days after childbirth. The IUD strings were not visible on examination, raising concern about the device's location.

Abdominal and pelvic CT was performed to investigate the suspected complication.

The subsequent clinical course was significant. Surgical exploration confirmed uterine fundal perforation and an IUD displaced into the pelvic cavity. The device was removed, and the perforation site was repaired.

Detailed vital signs, laboratory values, quantified blood loss, the type of IUD, and the patient's longer-term follow-up outcome were not reported in the available clinical information.

These missing details do not diminish the diagnostic importance of the imaging findings, but they limit conclusions about the severity of the initial hemorrhage and the patient's long-term recovery.

Why Missing IUD Strings Matter

Nonvisible IUD strings do not establish uterine perforation. Strings may retract into the cervical canal or uterine cavity, and the device may also have been expelled.

However, when abdominal pain accompanies missing strings, the device's actual location must be established.

The differential diagnosis includes:

  1. Retracted IUD strings with a normally positioned device.

  2. Partial or complete device expulsion.

  3. Intrauterine IUD malposition.

  4. Myometrial embedment.

  5. Partial uterine perforation.

  6. Complete uterine perforation with extrauterine migration.

The appropriate next step depends on the patient's symptoms, examination findings, and clinical stability.

Pathophysiology: How Does Uterine Perforation Occur?

Uterine perforation occurs when the uterine wall is breached, creating an abnormal passage between the uterine cavity and the extrauterine space.

The uterine wall comprises the endometrium, myometrium, and outer serosal surface. An IUD may become embedded in the myometrium or penetrate the wall partially or completely.

Partial Perforation

In partial perforation, the device penetrates the uterine wall but does not completely traverse it. Part of the device may remain within the uterine cavity while another portion is embedded in the myometrium.

Ultrasound may demonstrate an abnormally positioned device or penetration into the myometrium. CT can help clarify the relationship between the device and the uterine wall when the findings are uncertain or when additional complications are suspected.

Complete Perforation

Complete perforation occurs when the device passes through the full thickness of the uterine wall and enters the extrauterine space.

The device may remain near the uterus or migrate into the peritoneal cavity. Depending on its location, it may contact or adhere to adjacent structures, including the bowel, bladder, omentum, or mesentery.

In the present case, the combination of a full-thickness fundal defect and an extrauterine IUD established the key anatomic abnormality. The accompanying sentinel clot and hemoperitoneum indicated that bleeding was also present.

Why the Postpartum Period Deserves Special Attention

The uterus undergoes substantial anatomic and physiologic changes during pregnancy and after delivery. During the postpartum period, the uterus gradually involutes, returning toward its nonpregnant size and configuration.

The timing of IUD insertion is relevant to the risks of perforation and expulsion. Observational research, including the APEX-IUD cohort study, has identified differences in perforation risk according to the timing of insertion relative to childbirth. Breastfeeding has also been associated with an increased relative risk of perforation in some studies.

These associations should be interpreted carefully. Uterine perforation remains uncommon, and an increased relative risk does not mean that the complication is likely to occur in an individual patient.

The practical lesson is not to discourage postpartum contraception. Rather, clinicians should recognize the importance of appropriate insertion, follow-up, and prompt investigation when symptoms or missing strings raise concern about device position.

Imaging Evaluation: Ultrasound Versus CT

Ultrasound: The Initial Examination for IUD Localization

Pelvic ultrasound, particularly transvaginal ultrasound when appropriate, is generally the first-line imaging examination for evaluating IUD position.

It can assess:

  • Whether the device is within the endometrial cavity.

  • Whether the device is abnormally oriented.

  • Whether part of the device is embedded in the myometrium.

  • Whether the uterus contains other abnormalities relevant to the presentation.

Three-dimensional ultrasound may provide additional information about device orientation and its relationship to the uterine cavity.

However, failure to identify an IUD on ultrasound should not automatically be interpreted as device expulsion. If the strings are missing and the device cannot be confidently localized, further imaging may be necessary.

In a symptomatic patient, the investigation should also address whether the device has migrated beyond the uterus and whether a complication is present.

CT: Defining Perforation and Its Complications

CT is particularly valuable when acute abdominal pain raises concern for uterine perforation, intra-abdominal bleeding, or injury to adjacent organs.

In this case, CT provided evidence of four linked abnormalities: a full-thickness fundal defect, an extrauterine IUD, an adjacent sentinel clot, and hemoperitoneum.

A comprehensive CT assessment should address:

  1. Device location: Is the IUD within the endometrial cavity, embedded in the myometrium, or outside the uterus?

  2. Uterine wall integrity: Is there a focal interruption of the uterine wall?

  3. Hemorrhage: Is free fluid present, and does its attenuation suggest blood?

  4. Bleeding source: Is there a focal collection of relatively high-attenuation blood near the suspected perforation?

  5. Adjacent organs: Is the device in contact with or penetrating the bowel, bladder, omentum, or mesentery?

  6. Additional complications: Are there findings suggesting inflammation, infection, obstruction, or another acute abdominal process?

Multiplanar reconstructions are particularly useful for understanding the relationship between the uterine fundus, the perforation site, and the displaced device.

CT should be selected according to the clinical question and the patient's condition, rather than used automatically for every missing-string presentation. Radiation exposure, pregnancy status, contrast-related considerations, and the availability of ultrasound must be taken into account.

MRI may provide superior soft-tissue characterization in selected gynecologic conditions, but it is not usually the preferred examination when an acute presentation requires rapid assessment of hemoperitoneum and potential intra-abdominal injury.

CT Findings: Seven Key Imaging Observations

Figure 1. Sagittal Contrast-Enhanced CT: Full-Thickness Fundal Defect

Radiologic interpretation: The sagittal contrast-enhanced CT image demonstrates interruption of the normal uterine fundal wall, consistent with a transmural defect. Adjacent high-attenuation material is described in the case, supporting the presence of localized blood near the suspected perforation site.

Diagnostic significance: A focal interruption of the uterine wall is more concerning for perforation than isolated wall thinning or an abnormally positioned IUD. The relationship between the defect and adjacent hemorrhagic material helps localize the likely source of bleeding.

Clinical implication: A suspected full-thickness uterine defect accompanied by hemoperitoneum warrants urgent gynecologic assessment.

ALT text: Sagittal contrast-enhanced CT showing a full-thickness uterine fundal defect with adjacent hemorrhagic change in a postpartum patient with IUD perforation.


Figure 2. Axial Contrast-Enhanced CT: Abnormally Located IUD

Radiologic interpretation: The axial CT image demonstrates a radiopaque contraceptive device in a position that does not correspond to the expected central uterine cavity.

Diagnostic significance: The critical question is not simply whether the device is visible, but whether its position is anatomically compatible with normal intrauterine placement.

Clinical implication: An abnormally located IUD should prompt assessment of the uterine wall and surrounding pelvic structures to distinguish malposition from perforation.

ALT text: Axial contrast-enhanced CT demonstrating an abnormally located intrauterine contraceptive device in a patient with suspected uterine perforation.


Figure 3. Axial CT: IUD Within the Douglas Pouch

Radiologic interpretation: The IUD is described as being outside the uterus, within the pelvic cavity, in the pouch of Douglas, also known as the rectouterine pouch.

Diagnostic significance: An IUD located within the peritoneal cavity is fundamentally different from a device that remains inside the uterine cavity but is malpositioned. In the presence of a full-thickness uterine defect, this location supports complete perforation with extrauterine migration.

Clinical implication: The device's relationship to the rectum, bowel, uterus, and other pelvic structures should be assessed to identify potential involvement of adjacent organs.

ALT text: Axial CT showing an IUD in the pouch of Douglas outside the uterus, consistent with extrauterine device migration.


Figure 4. Noncontrast Axial CT: Device Localization and Blood Attenuation

Radiologic interpretation: Noncontrast CT can help characterize the attenuation of pelvic fluid or collections and confirm the location of the radiopaque device.

Diagnostic significance: Blood may appear hyperattenuating relative to simple fluid, although attenuation varies with the age and composition of the hemorrhage. Interpretation should account for the clinical setting and the full CT examination.

Clinical implication: Noncontrast images can complement contrast-enhanced images when differentiating hemorrhagic material from other pelvic contents.

ALT text: Noncontrast axial CT used to assess IUD location and the attenuation of suspected blood in the pelvis.


Figure 5. Delayed-Phase Contrast-Enhanced CT: Assessment of Hemorrhage

Radiologic interpretation: Delayed-phase imaging can provide additional information about contrast extravasation and the distribution of abnormal fluid when active bleeding is suspected.

Diagnostic significance: The absence or presence of visible contrast extravasation must be interpreted in relation to the acquisition timing and the patient's clinical condition. A negative study for active extravasation does not exclude clinically important hemorrhage.

Clinical implication: Additional phases should be obtained when clinically justified, rather than performed routinely without a specific diagnostic question.

ALT text: Delayed-phase contrast-enhanced CT for assessment of pelvic hemorrhage associated with uterine perforation.


Figure 6. Coronal Contrast-Enhanced CT: Uterus, Defect, and Pelvic Blood

Radiologic interpretation: Coronal reconstruction facilitates assessment of the uterine fundus, the suspected wall defect, and the distribution of blood within the pelvis.

Diagnostic significance: Multiplanar review helps confirm whether the suspected abnormality is a true wall defect and clarifies its spatial relationship to the displaced IUD.

Clinical implication: Coronal images complement axial and sagittal images and can improve communication of the location and extent of the abnormality to the treating team.

ALT text: Coronal contrast-enhanced CT demonstrating the relationship between the uterine fundus, suspected perforation, and pelvic hemorrhage.


Figure 7. Coronal Contrast-Enhanced CT: Multiplanar Confirmation

Radiologic interpretation: The additional coronal image provides a complementary view of the pelvic structures and supports the assessment of the previously identified abnormalities.

Diagnostic significance: A finding identified in one plane should be reviewed in orthogonal planes whenever possible. Multiplanar confirmation is especially useful when the uterine contour is altered, or the device lies near adjacent pelvic structures.

Clinical implication: The final report should communicate the suspected perforation site, the extrauterine location of the IUD, the presence of hemoperitoneum, and any suspected adjacent-organ involvement.

ALT text: Coronal CT reconstruction for confirmation of extrauterine IUD position and associated pelvic abnormalities.

The Sentinel Clot Sign: Localizing the Source of Bleeding

The sentinel clot sign is an important imaging clue in patients with hemoperitoneum.

It describes relatively high-attenuation blood that accumulates near the source of hemorrhage. Because blood close to the bleeding site may be more concentrated than blood distributed elsewhere in the peritoneal cavity, the finding can help identify the likely origin of the hemorrhage.

In this case, the sentinel clot was described adjacent to the uterine fundal defect.

The diagnostic value comes from the combination of findings rather than the clot alone:

Full-thickness uterine defect + adjacent sentinel clot + hemoperitoneum + extrauterine IUD

This pattern strongly supports uterine perforation with associated intra-abdominal bleeding.

A sentinel clot does not independently prove the precise source of hemorrhage. Its location must be interpreted alongside the uterine anatomy, device position, contrast-enhanced findings, and clinical presentation.

Hemoperitoneum: Why It Changes the Clinical Priority

Hemoperitoneum refers to blood within the peritoneal cavity. In a patient with suspected IUD-related uterine perforation, it raises concern for a clinically significant complication rather than an isolated device-position abnormality.

The severity of hemorrhage cannot be determined from the presence of free fluid alone. Relevant considerations include the amount and distribution of blood, the patient's hemodynamic status, the presence of active contrast extravasation, and the need for intervention.

In the present case, hemoperitoneum accompanied the fundal defect, sentinel clot, and extrauterine IUD. The combination prompted urgent surgical exploration.

The imaging report should therefore avoid an overly narrow conclusion such as “IUD malposition.” It should explicitly communicate the suspected full-thickness perforation and associated hemorrhage.

When urgent findings are identified, direct communication with the treating team is an important part of the diagnostic process.

Differential Diagnosis: Malposition, Expulsion, and Uterine Rupture

1. IUD Expulsion

Expulsion occurs when the device passes partially or completely through the cervix and out of the uterus.

Missing strings can accompany expulsion, but an expelled device is not expected to remain freely within the peritoneal cavity as a consequence of simple expulsion.

An extrauterine IUD combined with a full-thickness uterine defect strongly favors perforation.

2. IUD Malposition

Malposition refers to an IUD that remains within the uterus but is not in its expected position.

A low-lying device, an abnormally oriented device, or a device embedded in the myometrium may be malpositioned without complete perforation.

The distinction is clinically important because intrauterine malposition and complete uterine perforation require different assessments and may lead to different management decisions.

Malposition is not synonymous with perforation.

3. Partial Uterine Perforation

Partial perforation occurs when the device penetrates the uterine wall without completely traversing it.

The device may appear embedded in the myometrium. Demonstrating its relationship to the endometrial cavity and the outer uterine contour helps distinguish partial from complete perforation.

4. Uterine Rupture

Uterine rupture is a full-thickness disruption of the uterine wall that may occur in pregnancy or in association with childbirth. It can cause intra-abdominal hemorrhage and requires urgent evaluation.

Although a uterine wall defect and hemoperitoneum may be seen in both conditions, the presence of an IUD outside the uterus provides an important clue favoring device-related perforation in this case.

The clinical history, timing, uterine anatomy, and relationship between the device and the defect should guide the distinction.

5. Postpartum Pelvic Infection

Postpartum infection can cause abdominal pain, fever, and pelvic inflammatory changes. Imaging may demonstrate inflammatory abnormalities or associated collections.

However, infection alone does not adequately explain a full-thickness fundal defect with an extrauterine IUD. Infection may coexist with another process, but the mechanical abnormality must be addressed directly.

A Practical CT Interpretation Algorithm

A structured review can reduce the risk of overlooking a significant device-related complication.

Step 1: Confirm the clinical context.
Establish the postpartum interval, the history of IUD placement, the presenting symptoms, and whether the strings are visible.

Step 2: Locate the IUD.
Determine whether the device is within the endometrial cavity, embedded in the myometrium, or outside the uterus.

Step 3: Inspect the uterine wall.
Look for a focal defect, abnormal contour, or interruption of the expected wall.

Step 4: Establish the relationship between the device and the defect.
Determine whether the device appears to have traversed the uterine wall.

Step 5: Evaluate free fluid.
Assess the amount, distribution, and attenuation of pelvic and abdominal fluid.

Step 6: Search for a sentinel clot.
Look for relatively high-attenuation blood near the suspected source of hemorrhage.

Step 7: Assess adjacent organs.
Review the bowel, bladder, omentum, and mesentery for direct contact, suspected penetration, or secondary complications.

Step 8: Evaluate for active bleeding when appropriate.
Review the available contrast phases for extravasation, while recognizing that its absence does not exclude hemorrhage.

Step 9: Communicate urgent findings.
Promptly notify the responsible clinical team when complete perforation, hemoperitoneum, or possible organ injury is identified.

Why This Diagnosis Can Be Missed

One potential perceptual error is focusing on the radiopaque IUD while failing to evaluate the surrounding uterine wall.

A device may be readily visible on CT, but visibility alone does not establish whether its location is expected or whether an associated complication is present.

Several factors can contribute to diagnostic oversight:

  • Attention directed primarily toward the device rather than the uterine contour.

  • Failure to review the examination in multiple planes.

  • Underrecognition of small volumes of hemoperitoneum.

  • Failure to identify the sentinel clot.

  • Incomplete assessment of the relationship between the device and adjacent organs.

  • Communication delays when an urgent abnormality is identified.

These are potential system-level vulnerabilities, not evidence that any particular clinician made an error in this case.

A structured search pattern and explicit reporting of the device's location, uterine wall integrity, and associated bleeding can improve the completeness of interpretation.

Can Artificial Intelligence Help Detect IUD-Related Uterine Perforation?

Artificial intelligence (AI) may eventually support aspects of abdominal and pelvic imaging review, but its role in this specific clinical scenario requires careful qualification.

No AI system was reported as being used in this case, and no AI performance data are available. It would therefore be inappropriate to claim that an algorithm could have detected the perforation or improved the outcome.

Potential areas for future development include:

  • Device localization: Identifying radiopaque IUDs on CT and helping characterize their position relative to the uterus.

  • Abnormality detection: Flagging possible pelvic hemorrhage or unexpected extrauterine devices for radiologist review.

  • Workflow prioritization: Helping prioritize examinations when findings suggest an urgent abdominal or pelvic complication.

  • Structured reporting: Supporting consistent documentation of the device location, uterine wall findings, hemoperitoneum, and possible adjacent-organ injury.

These are potential applications, not established performance claims for this diagnosis.

Important AI Limitations

A radiology AI system developed for other abdominal abnormalities may not reliably identify a rare complication such as IUD-related uterine perforation.

Potential limitations include:

  • Limited representation of rare cases in training datasets.

  • False-positive alerts caused by unrelated pelvic structures or artifacts.

  • False-negative results when the defect is subtle.

  • Reduced performance in patients with altered postpartum anatomy.

  • Differences in scanner protocols and image quality.

  • Workflow interruptions and alert fatigue.

  • Limited generalizability across hospitals and patient populations.

Clinical deployment would require appropriate validation, assessment of false-positive and false-negative results, and evaluation of how alerts affect radiologist performance and workflow.

AI should function as decision support rather than a substitute for clinical judgment. The radiologist remains responsible for integrating imaging findings with the patient's presentation and communicating urgent abnormalities.

Clinical Workflow and Healthcare-System Implications

The importance of this case extends beyond identifying an abnormal IUD position.

A delayed diagnosis of complete uterine perforation may allow bleeding or injury to adjacent organs to remain unrecognized. If a migrated device becomes adherent to or penetrates an adjacent structure, subsequent treatment may become more complex.

A useful clinical workflow connects three stages:

  1. Recognition: Identify the uterine defect, displaced device, and evidence of hemorrhage.

  2. Communication: Provide a clear, timely report and directly communicate urgent findings.

  3. Action: Support appropriate gynecologic or surgical evaluation based on the patient's condition and the suspected complications.

From a healthcare-system perspective, structured reporting and effective communication may help reduce avoidable delays and improve coordination between radiology, emergency medicine, and gynecologic surgery.

However, the available case information does not quantify any reduction in turnaround time, hospital costs, complications, or length of stay. These benefits should be treated as plausible workflow objectives rather than demonstrated outcomes of this individual case.

Treatment and Surgical Management

Management depends on the patient's clinical stability, the location of the device, the presence of bleeding, and the possibility of injury to adjacent organs.

In the present case, surgical exploration was performed immediately after CT. The procedure confirmed uterine fundal perforation and an IUD in the pelvic cavity. The device was removed, and the perforation site was repaired.

Stable Patients

In selected patients, minimally invasive surgery may be appropriate. Laparoscopy can facilitate retrieval of an extrauterine IUD and inspection of the pelvic cavity. Hysteroscopy may be useful when the device remains within the uterine cavity or when intrauterine evaluation is indicated.

The appropriate approach depends on the location of the device and the presence of complications.

Patients With Hemoperitoneum or Suspected Organ Injury

When imaging demonstrates hemoperitoneum or raises concern for bowel or bladder injury, urgent gynecologic and surgical evaluation is warranted.

The choice between laparoscopy, laparotomy, and other interventions depends on the patient's hemodynamic condition, the severity of bleeding, and the suspected extent of injury.

An extrauterine device should not be managed solely on the basis of its presence or absence on imaging. Its relationship to surrounding structures and the clinical risks associated with leaving it in place must be considered.

Prognosis and Potential Complications

Early recognition and appropriate management can lead to a favorable outcome, but prognosis depends on the extent of perforation and the presence of associated complications.

Potential complications include:

  • Intra-abdominal bleeding.

  • Peritonitis or pelvic infection.

  • Bowel or bladder injury.

  • Bowel perforation or obstruction.

  • Adhesion formation.

  • Persistent pelvic pain.

  • The need for additional surgery.

These are recognized potential complications, not outcomes documented in this patient.

The available case information confirms operative treatment and repair of the uterine fundal defect. It does not provide sufficient follow-up information to establish the patient's long-term outcome.

Frequently Asked Questions

What is the most important CT finding in IUD-related uterine perforation?

The most important finding is a full-thickness defect in the uterine wall associated with an IUD outside the uterine cavity. Hemoperitoneum and an adjacent sentinel clot strengthen the diagnosis of perforation with associated bleeding.

Can an IUD perforate the uterus after childbirth?

Yes. Uterine perforation is a recognized, uncommon complication of IUD insertion. The timing of insertion relative to childbirth is relevant to risk, and postpartum patients with abdominal pain or missing strings require appropriate assessment.

Does a missing IUD string mean the device has perforated the uterus?

No. Strings may retract, and the device may have been expelled or may be malpositioned within the uterus. Imaging is used to establish the device's location and investigate suspected complications.

Is ultrasound or CT better for detecting uterine perforation?

Ultrasound is generally the initial examination for evaluating IUD position. CT is particularly useful when acute abdominal pain, hemoperitoneum, extrauterine migration, or adjacent-organ injury is suspected. The appropriate modality depends on the clinical question.

What does a sentinel clot mean on CT?

A sentinel clot is relatively high-attenuation blood near the likely source of hemorrhage. It helps localize bleeding but must be interpreted together with the other imaging findings.

Does every extrauterine IUD cause hemoperitoneum?

No. Extrauterine migration does not invariably produce significant bleeding. The presence and severity of hemorrhage must be assessed independently, together with possible injury to adjacent organs.

How is complete uterine perforation treated?

Treatment depends on the patient's condition, the device's location, and associated complications. Surgical removal of an extrauterine IUD and repair of the perforation may be required, particularly when bleeding or organ injury is suspected.

Radiology Pearls: What to Remember

  1. Missing IUD strings are a clinical clue, not a diagnosis. Establish the device's actual location.

  2. Abdominal pain changes the level of concern. Perforation should be considered when symptoms accompany missing strings.

  3. The uterine wall matters as much as the device. Look for a focal defect and establish its relationship to the IUD.

  4. A full-thickness defect supports complete perforation. Distinguish it from intrauterine malposition or partial embedment.

  5. The sentinel clot helps localize hemorrhage. Look for relatively high-attenuation blood adjacent to the suspected source.

  6. Hemoperitoneum increases clinical urgency. Assess its distribution and communicate significant findings promptly.

  7. Review adjacent organs. A displaced device may involve the bowel, bladder, omentum, or mesentery.

  8. Use multiplanar CT review. Axial, sagittal, and coronal images provide complementary anatomic information.

  9. AI is a potential support tool, not a proven solution for this rare complication. Performance must be validated before clinical use.

  10. Early recognition and clear communication are essential. Imaging should guide timely clinical assessment and appropriate treatment.

Conclusion

Uterine perforation after IUD placement is uncommon, but it can have serious consequences when accompanied by intra-abdominal bleeding or injury to adjacent organs.

In this 30-year-old woman presenting with abdominal pain approximately 40 days after childbirth, CT demonstrated the key combination of a full-thickness uterine fundal defect, an adjacent sentinel clot, an extrauterine IUD in the pelvic cavity, and hemoperitoneum. Surgical exploration confirmed the perforation, and the device was removed before the uterine defect was repaired.

The central lesson for radiologists is straightforward: when an IUD is not in its expected position, evaluate the uterine wall, look for hemorrhage, and assess adjacent organs.

Recognizing these findings as a connected pathologic process, rather than treating them as isolated abnormalities, can support timely diagnosis and appropriate management.

Continue Learning | Medical Imaging and Clinical AI

Explore these related topics within the ScholarGen MediAI knowledge network:

  1. CT Evaluation of Hemoperitoneum: Identifying high-attenuation blood and localizing the source of intra-abdominal hemorrhage.
    [INTERNAL LINK PLACEHOLDER]

  2. CT Imaging of Acute Pelvic Pain in Women: A structured approach to urgent gynecologic and nongynecologic conditions.
    [INTERNAL LINK PLACEHOLDER]

  3. Ultrasound and CT for IUD Localization: How to evaluate missing strings, malposition, embedment, and extrauterine migration.
    [INTERNAL LINK PLACEHOLDER]

  4. Imaging Findings of Postpartum Complications: Recognizing hemorrhagic, inflammatory, and structural abnormalities after childbirth.
    [INTERNAL LINK PLACEHOLDER]

  5. AI in Emergency Radiology: Clinical validation, workflow integration, false-positive alerts, and human oversight.
    [INTERNAL LINK PLACEHOLDER]

References

  1. Reed SD, et al. Intrauterine device-related uterine perforation incidence and risk (APEX-IUD): a large multisite cohort study. The Lancet. 2022;399(10341):2103–2112. doi: 10.1016/S0140-6736(22)00015-0.

  2. Fassett MJ, et al. Risks of uterine perforation and expulsion associated with intrauterine devices. Obstetrics & Gynecology. 2023;142(3):641–651. doi: 10.1097/AOG.0000000000005299.

  3. Zhu GG, et al. CT imaging of intrauterine devices (IUD): expected findings, unexpected findings, and complications. Abdominal Radiology. 2024;49(1):237–248. doi: 10.1007/s00261-023-04052-3.

  4. Nowitzki KM, et al. Ultrasonography of intrauterine devices. Ultrasound Quarterly. 2015;34(3):183–194. doi: 10.14366/usg.15010.

  5. Kaislasuo J, et al. Uterine perforation caused by intrauterine devices: clinical course and treatment. Human Reproduction. 2013. doi: 10.1093/humrep/det074.

  6. Goldthwaite LG, et al. Postpartum intrauterine devices: clinical and programmatic review. American Journal of Obstetrics & Gynecology. 2018;219(3):235–241. doi: 10.1016/j.ajog.2018.07.013.

  7. Kapp N, Curtis KM. Intrauterine device insertion during the postpartum period: a systematic review. Contraception. 2009;80(4):327–336. doi: 10.1016/j.contraception.2009.03.024.

  8. Berry-Bibee EN, et al. The safety of intrauterine devices in breastfeeding women: a systematic review. Contraception. 2016;94(6):725–738. doi: 10.1016/j.contraception.2016.07.006.

Medical Disclaimer

This article is intended for medical education and professional information. It does not replace individualized medical assessment, clinical judgment, or institutional protocols. Imaging findings must be interpreted in the context of the patient's clinical presentation. Suspected uterine perforation with hemoperitoneum requires urgent clinical evaluation. Treatment decisions should be made by qualified healthcare professionals.

© ScholarGen MediAI. All rights reserved.